Pin Specifications

Pin Configuration
PIN NAME FUNCTION
Pin Description
1 RADDR Device ID Resistor. Connect a resistor value from RADDR to GND to set the UART Device ID.
2 RGRADE LED Binning Resistor Connection. Connect a LED binning resistor from this pin to GND.
3, 26 RX UART Receive Input. If the driver to this pin is CMOS output, no pull-up resistor is needed. If the driver to this pin is open drain, add a 1.5kΩ pull-up resistor.
4, 25 TX UART Transmit Output. Add a 1.5kΩ pull-up resistor.
5 CLKIN CLK Input. Can be optionally used to sync the device with an external digital clock signal.
6 RTEMP NTC Divider ADC Input. Connect to NTC resistor divider to enable remote temperature sensing.
7 VDD LDO Output. Nominal voltage is 1.8V. Connect a bypass capacitor between VDD and GND.
8 DR12 Drain of Internal Switch 12. Add a 0.1μF capacitor from DR12 to GND.
9 DR11 Drain of Internal Switch 11.
10 DR10 Drain of Internal Switch 10.
11 DR9 Drain of Internal Switch 9.
12 DR8 Drain of Internal Switch 8.
13 DR7 Drain of Internal Switch 7.
14 SRC7 Source of Internal Switch 7.
15 DR6 Drain of Internal Switch 6. For two-string applications, connect a 0.1μF ceramic capacitor from DR6 to GND.
16 DR5 Drain of Internal Switch 5.
17 DR4 Drain of Internal Switch 4.
18 DR3 Drain of Internal Switch 3.
19 DR2 Drain of Internal Switch 2.
20 DR1 Drain of Internal Switch 1.
21 SRC1 Source of Internal Switch 1.
22 CPP Charge Pump Capacitor Positive Connection. Connect a 0.1µF ceramic capacitor from CPP to CPN.
23 CPN Charge Pump Capacitor Negative Connection. Connect a 0.1µF from CPP to CPN.
24 CLKOUT After startup, can be optionally configured with UART to drive a clock signal to other devices, or act as a pass-through for the CLKIN input.
27 FLT Open-Drain Fault Indicator. Goes low when a fault condition is present.
28 IN Connect external bypass capacitor to GND.
EP/GND Exposed Pad Ground Connection. Connect this pad to a contiguous ground plane.