Pin Specifications

Pin Configurations MAX14914 and MAX14914A
MAX14914B
PIN NAME FUNCTION TYPE
MAX14914 and MAX14914A MAX14914B
Pin Description
1 1 VL Logic Supply Input. VL defines the levels on all I/O logic interface pins. Bypass VL to GND through a 100nF ceramic capacitor. Supply
2 2 GND Analog Ground Supply
3 3 CLIM Current Limit Set Input. Connect a resistor from CLIM to GND to set the current limit. See Detailed Description for further information. Analog Input
4 4 FAULT Open-Drain Fault Output. The FAULT transistor turns on when a fault condition (driver thermal shutdown or loss of ground) occurs. Connect a pullup to VL or V5. Logic Output
5 5 DOI_LVL Open-Drain DOI Level Output. DOI_LVL is logic-low when DOI voltage is higher than the threshold voltage. DOI_LVL is logic-high (using a pullup resistor) when DOI voltage is lower than the  threshold voltage. The threshold voltage depends on DI_EN. Connect a pullup to VL or V5. Logic Output
6 6 DI_EN Digital Input Mode Logic Enable Input. Set DI_EN high to enable digital input operation on the DOI pin, which enables the internal current sink and sets Type 1, Type 2, or Type 3 thresholds on DOI_LVL. Select between Type 1 and 3, and Type 2 DI characteristics through the PP input. Analog
7 7 IN Switch Control Input. Drive IN high to close the HS switch; drive IN low to open the HS switch and close the LS switch (when PP = low). Logic Input
8 8 PP Push-Pull DO or DI Type Select Input. In DO mode, set PP high to enable push-pull mode operation of the DO driver. In DI mode, set PP low for IEC Type 1/3 input characteristics and set high for Type 2 input characteristics. Logic Input
9 9 PGND Power Ground Supply
10, 11 10, 11 DOI High-Side / Push-Pull Output (DI_EN = low) or Digital Input (DI_EN = high). Connect both DOI pins together externally. Power
12, 13 12, 13 VDD Supply Voltage, Nominally 24V. Bypass VDD to GND through a 1uF capacitor. Supply
14 14 REGIN 5V Regulator Input. Connect REGIN to VDD when using the internal 5V regulator. Connect REGIN to V5 when powering V5 from an external regulator. Supply
15 OV_VDD Open-Drain Overvoltage Output for the MAX14914 and MAX14914A. The OV_VDD transistor turns off when: 1) a device configured for DI operation; 2) DOI level is higher than VDD. Connect a pullup to VDD.
15 OV_CURR Open-Drain Overcurrent Output for the MAX14914B. OV_CURR turns active low when the load current exceeds the high-side current limit. Connect a pullup resistor between OV_CURR and VL.
16 16 V5 Analog Supply Voltage/LDO Output. The MAX14914 requires a 5V supply for normal operation, which can come from the internal linear regulator (REGIN connected to VDD) or from an external regulator (REGIN connected to V5). Bypass to GND through a 1μF ceramic capacitor. Supply
EP Exposed Pad. Connect EP to GND.